Power Source Compatibility Chart

COMPATIBLE NOT COMPATIBLE
XMT® 350 FieldPro™ systems XMT® 350 VS systems with ArcReach® technology
XMT® 350 FieldPro™ systems with Polarity Reversing XMT® 450 VS systems with ArcReach® technology
PipeWorx 350 FieldPro™ systems XMT® 350 CC/CV systems with ArcReach® technology
Dimension™ 650 systems with ArcReach® technology* XMT® 450 CC/CV systems with ArcReach® technology
Big Blue® engine-driven welders with ArcReach® technology Legacy Dimension™ 650 systems with ArcReach® technology*
Trailblazer® 325 engine-driven welders with ArcReach® technology
Legacy engine-driven welders with ArcReach® technology and Smart Feeder capability  
*ONLY DIMENSION™ 650 MACHINES MANUFACTURED AFTER 3/16/2021 ARE COMPATIBLE. To confirm compatibility, look for ArcReach Heater Compatibility Icon on the machine faceplate or email ISGservice@millerwelds.com.


Heating Tools Compatibility Charts

HEATING TOOLS FOR ARCREACH® HEATER**


AIR-COOLED CABLES AIR-COOLED QUICK WRAP
Max. Preheat Temperature
Verify insulation requirements using this chart.
600°F (315°C) 600°F (315°C)
Pipe Diameter Range 3/4 in. (1.9 cm) and up 1.5 in. (3.8 cm) to 10 in. (25.4 cm)
Available Cable Lengths 30 ft. (9.1 m), 50 ft. (15.2 m), 80 ft. (24.4 m)* N/A
Amperage Capability 250 A max./200 A continuous 165 A max./115 A continuous
*Optional series adapter can extend length of cable.
**Liquid-cooled cables, air-cooled blankets and rolling inductor are not compatible with ArcReach Heater systems.



HEATING TOOLS FOR ARCREACH® HEATER AND PROHEAT™ 35

 
AIR-COOLED QUICK WRAP
AIR-COOLED CABLES
AIR-COOLED BLANKETS
ROLLING INDUCTOR
LIQUID-COOLED
CABLES
Max. Preheat Temperature 600°F (315°C) 600°F (315°C): ArcReach Heater
400°F (204°C): ProHeat 35
400°F (204°C) 600°F (315°C) 1,450°F (788°C)
Pipe Diameter* 1.5 in. (3.8 cm)
to 10 in. (25.4 cm)
3/4 in. (1.9 cm) and up 8–60 in. (20-152 cm) Unlimited 3/4 in. (1.9 cm) and up
Available Cable Lengths N/A 30 ft. (9.1 m), 50 ft. (15.2 m), 80 ft. (24.4 m) N/A 30 ft. (9.1 m),
50 ft. (15.2 m),
80 ft. (24.4 m),
140 ft. (42.7 m),
160 ft. (48.8 m)
N/A
Requires Coolant/ Cooler No No No Yes Yes
Amperage Capability 165 A max./115 A continuous 250 A max./200 A continuous 250 A max./150 A continuous 300 A max. 350 A max.
Width 3.7 in. (9.4 cm) N/A Dependent on length of blanket 5 in. (12.7 cm) square heating area N/A
Compatible With ProHeat™ 35  
Compatible With ArcReach® Heater      

*All tools except for the air-cooled quick wrap can also be used on flat plates and various other applications.



APPLYING PREHEAT INSULATION (IF REQUIRED)

PART TEMP ½ IN. PREHEAT INSULATION REQUIREMENTS*
ºF (ºC) AIR-COOLED QUICK WRAP AIR-COOLED CABLE
122–302 (50–150)
302–392 (150–200) 1 layer
392–482 (200–250) 1 layer 1 layer
482–600 (250–315) 1 layer 2 layers
*To help avoid damage to heating tool, always protect it by applying insulation on the workpiece anywhere the tool will be placed. Note that in some instances, adding a layer of insulation may increase kW output; be sure to check the parameter screen to monitor kW output on setup.