*All tools except for the air-cooled quick wrap can also be used on flat plates and various other applications.
APPLYING PREHEAT INSULATION (IF REQUIRED)
PART TEMP |
½ IN. PREHEAT INSULATION REQUIREMENTS* |
ºF (ºC) |
AIR-COOLED QUICK WRAP |
AIR-COOLED CABLE |
122–302 (50–150) |
— |
— |
302–392 (150–200) |
— |
1 layer |
392–482 (200–250) |
1 layer |
1 layer |
482–600 (250–315) |
1 layer |
2 layers |