  • You need miller tech manual T232B . to match your serial number, Try miller literature .
    Or ask nicely some one here might be able to slip you one.
    See more | Go to post

    Leave a comment:


  • Do you have 3 phase power connected to this welder? It is a 3 phase only welder.
    using the diagram pasted to the cover, find to voltage feedback wires to the pcb. Make sure they are not open.
    Check diode SCR assembly for shorts. If any diodes or SCRs are bad they are not available from Miller....
    See more | Go to post

    Leave a comment:


  • ccawgc
    replied to Connectors
    If you are talking about frame ground to earth. It is not required unless you using the welder for standby power AND connected to a building electrical system. Welding or work "ground" carries weld current . Only time this should be earth grounded is if you are TIG welding with HF. Remember...
    See more | Go to post

    Leave a comment:


  • ccawgc
    replied to Farm Needs 252 or 350p
    Only one thing to add about pulse. The gas mix is different. 90/10 to 98/2. Pulse uses spray arc mix. short arc mix is 75/25.
    See more | Go to post

    Leave a comment:


  • the location on the pcb look like the SCR gating system. If the resister was burnt, then the pulse transformer is open and the cause is a bad weld SCR..
    You are going to need to test the SCRs and make sure they turn on. Basic ohm meter is not able to turn on a SCR. You can measure where the SCR...
    See more | Go to post
    Last edited by ccawgc; 07-22-2016, 01:41 PM.

    Leave a comment:


  • ccawgc
    replied to millermatic 185 overheating
    You can have your electrician check the switch when the welder shuts down and see if it opens up. That will tell you if the problem is the switch, after the switch, or in the line cord and plug, or the wall power or circuit breaker.
    See more | Go to post

    Leave a comment:


  • ccawgc
    replied to Multiprocess machine
    None that I can think of in an all in one package. You other choice is a shopmaster which is a AC/DC stick Mig power source. But to that you will need to add a feeder like a 22A and a HF arc start box for the tig. Depending on which version of the shopmaster you can find will determine what controls...
    See more | Go to post

    Leave a comment:


  • ccawgc
    replied to Help needed for Syncrowave 300
    Cooler by its self should shoot coolant some distance. No hoses attached.
    Connected the blue hose to the cooler out put and disconnect the red from the power block.
    Should be a steady low pressure flow. should easily fill a quart jar in around a minute or two.
    these two test will point...
    See more | Go to post