Miller Dimension 452
 
ESAB Multi-power 460
 
Lincoln DC 400
 
Comments
Process DC: CC/CV   DC: CC/CV   DC: CC/CV   DC: CC/CV   Comparable
Rating 450 A @ 38 volts   450 A @ 38 volts   450 A @ 38 volts   400 A @ 36 volts   (Lincoln Disadvantage) lacks 50A and 2 volts.
Duty Cycle 450 @ 100%   450 @ 100%   450 @ 100%   400 @ 100%   (Lincoln Disadvantage) lacks 50A.
Weight 380 lbs.   424 lbs.   322 lbs.   473 lbs.   ESAB uses Plastic and SS. Heavy gauge steel side panels and cover. Larger transformer.
CC Amperage Range 5-500A   20-565A   10-500A   60-500A   (Lincoln Disadvantage) Lacks in low end performance.
CV Voltage Range 10-38V   10-38V   12-40V   12-42V   Excellent low end on this product very similar to ALT.
Meters Digital w/hold feature   Digital   Digital   Analog   (Lincoln Disadvantage) Digital Meters are easy to read and allow operators to monitor welding parameters after welding.
Presettable Meters Yes   Yes   Yes   No   (Lincoln Disadvantage) Allows operators to make precise settings.
High Temperature shutdown Std.   Std.   Std.   Std.   Comparable
Fan-on Demand™ Yes   Yes   Fan as needed   No   Miller Exclusive! Fan-on-demand
14 Pin. Protection (Ckt.Bkr.) 24/115   24/115   42/115   42/115   Comparable
115 VAC Duplex Receptacle Yes   Yes   Yes   Yes   Comparable
MAX OCV-DC 80VDC   65VDC   80VDC   78VDC   Enhanced starting performance.
Receptacle/remote controls 14 Pin   14 Pin   2 separate 1-WF   14 Pin 1-remotes   "Less clutter on front panel, operator friendly."
Arc Force Control Variable   Variable   Variable   Variable   Comparable
Input voltages Available 230/460/575   200/230/460/575   230/460/575   230/460   Comparable
Auto Remote Sense Std.   N/A   N/A   N/A   New! Automatically selects remote control requirements. Minimize switches!
Electronic Inductance Control Std.   N/A   Std.   N/A   New! Added flexibility for a large variety and diameter of wires and gases.
Mode Switch Yes   Selector Switch   Additional Switches   Optional control box   New! Automatically sets contactor requirements eliminating confusing switches!
Lift-arc TIG Yes   N/A   N/A   N/A   Miller Exclusive! Added Flexibility w/o tungsten contamination from scratch start.
Dimensions (H x W x D) 32.5" X 23" X 38"   32.5" X 23" X 38"   25" X 18.8" X 32.5"   27.5" X 22.3" X 33.1"   Easier access for serviceability.
Primary volt linkage access Rear Access Door   Rear Access Door   Cover Removal   Rear Access Door   Ease of primary linkage and primary power connections.
Help Error Codes 8 Help Messages   N/A   N/A   N/A   Miller Only! Reduces down time.
Critical components enclosures Yes   Yes   Exposed to environment   N/A   Additional component protection for harsh environments.
Warranty Advertised 3 Yrs. P/L and 5 Yrs. Main Rect.   Advertised 3 Yrs. P/L and 5 Yrs. Main Rect.   2 Years P/L   3 Years P/L   Best Advertised Warranty in the business! "True Blue"
Easy Primary Hookup No lugs needed on primary wires   No lugs needed on primary wires   No lugs needed on primary wires   No lugs needed on primary wires   Comparable
Strain Relief Std.   Std.   Std.   Std.   Comparable
Sides and Cover Material Steel   Steel   Plastic   Steel   Steel sides and cover add strength and rigidity.
Base Material Steel   Steel   Stainless Steel   Steel   Steel bases are heavier gauges. Added strength.